r/accesscontrol • u/Complex_Ad_4146 • 20h ago
Paxlock Pro
Has anyone experineced this is with Paxton Net2 Handles>
we use some at my work and they seem to start slipping and degrading after a year?
r/accesscontrol • u/Complex_Ad_4146 • 20h ago
Has anyone experineced this is with Paxton Net2 Handles>
we use some at my work and they seem to start slipping and degrading after a year?
r/accesscontrol • u/themanhammer84 • 3h ago
I have plenty of power to use inside this thing. However, there is no posts to mount a Brivo PSB that uses a 4 wire connection to provide power the ACS6100DB door boards. Can I power these door boards from the altronix power supplies inside the enclosure? The 4 posts are +12v, GND, POWER DET, Earth Ground. Has anyone tried to power these with anything but the PSB?
r/accesscontrol • u/TofuTank • 11h ago
My controller is throwing a code 91 during open AND close, even with the gate arm disconnected from the unit. The unit is a little over a year old. Some steps I’ve already taken:
-Power cycled by disconnecting AC and battery
-used multimeter to check AC and battery, both check out
-reset limits while under load and not under load
-checked wiring, reseated connections
-checked for any signs of undue load on the motor, no noise, vibration, nothing
-replaced APE, which oddly had it working fine for about 8 hours
-ordered new battery just in case, not arrived/installed yet
Any ideas? It’s driving me nuts, thanks!
r/accesscontrol • u/nickenzi • 13h ago
Hello,
We had a KT-400 slave controller go belly up on us. We replaced the controller and updated the serial number under that controller in EntraPass, however it still isn't seen/communicating. Are there any other steps that we may have missed?
Thank you!