r/PLC • u/TheCried • 2h ago
Meme Powerflex are Trash
Can't help thinking this every time I use a trash bag
r/PLC • u/xenokilla • 15d ago
READ FIRST: How to learn PLC's and get into the Industrial Automation World
Ask your questions below! The thread is sorted by New, so the latest questions are at the top. Thread will stay open indefinitely.
Feel free to visit:
* r/PLC_Career_Advice/
* /r/PLCcareers
* /r/IndustrialAutomation
* /r/industrialengineering
* /r/IndustrialMaintenance
r/PLC • u/1Davide • Sep 01 '26
**Company:** [Company name; also, use the "formatting help" to make it a link to your company's website, or a specific careers page if you have one.]
**Type:** [Full time, part time, internship, contract, etc.]
**Description:** [What does your company do, and what are you hiring people for? How much experience are you looking for, and what seniority levels are you hiring for? The more details you provide, the better.]
**Location:** [Where's your office - or if you're hiring at multiple offices, list them. If your workplace language isn't English, please specify it.]
**Remote:** [Do you offer the option of working remotely? If so, do you require employees to live in certain areas or time zones?]
**Travel:** [Is travel required? Details.]
**Visa Sponsorship:** [Does your company sponsor visas?]
**Technologies:** [Required: which microcontroller family, bare-metal/RTOS/Linux, etc.]
**Salary:** [Salary range]
**Contact:** [How do you want to be contacted? Email, reddit PM, telepathy, gravitational waves?]
Previous Post:
r/PLC • u/TheCried • 2h ago
Can't help thinking this every time I use a trash bag
Morning,
I’ve done various small projects but about to undertake a project which will have different alarms. How is best to handle alarms which will cause other parts of the machine to alarm? Ideally I want to capture the initial alarm not any of the secondary alarms/faults.
How is best to do this?
r/PLC • u/AgonyIsKey • 1h ago
I saw the news that this PHP vulnerability had just come up. Then, it dawned on me just how screwed up it would be if this vulnerability was used to take whole plants offline.
How does this impact PLCs? How susceptible are they?
What steps can we take on an integrator level to mitigate the vulnerability?
Are any plants already taking steps?
How would we protect legacy systems that 100% do not have the means to protect themselves?
r/PLC • u/imnotmarvin • 1d ago
I've been on both sides of the argument for and against this. Currently as a builder with gas processing programs that control potentially hazardous processes. Our director does not want to provide passwords to give the customer access to the running programs fearing they might attempt a modification that could result in injury, death or damage. Do you open your programs to the end user? We provide graphical insight to all IO, digital and analog, process state and valves status via an HMI.
r/PLC • u/xsheepful • 6h ago
Hi,
Ive recently installed VirtualBox, using an XP iso and installer RSLogix5000 v13.04 as we I need a backup for getting online in the interim.
Ive got the software, got FT Activation Manager, installed dongle for licensing and can see the binding and licences within available activations. Whenever I try to open Logix5000 it just comes up with no activations available.
Anyone had any success with this or seen a similar issue?
r/PLC • u/StivenPerez • 19h ago

I am using FTLinx Gateway to read data via OPC UA. The issue is that after adding 65 UA Tag Lists, I am no longer able to select additional PLCs to retrieve data from them. In FTLinx Gateway, I can see a total of 67 PLCs, yet I have configured 86 in the FactoryTalk Network Browser / FactoryTalk Administration Console.
The version of FTLinx Gateway is 6.60.00, and I have a LINXGW.PROFESSIONAL license.
I hope you can assist me; thank you.
r/PLC • u/szarman_ • 23h ago
Has anyone evaluated the SLM-RP4 from www.synergy-logic.com ? It looks like it is a RevPi competitor. It runs openplc, has I/O cards, and UL/CE.
r/PLC • u/Beneficial-Risk-3493 • 1d ago
I keep seeing these wireless preventative maintenance sensors online that capture motor vibration and temperature.
I was wondering if any of you guys had any experience implementing these sensors on the shop floor. I’m looking for a similar sensor, but it plugs back to the PLC where the alarms are generated and handled.
Does anyone have any suggestions. I see that automation direct has some analog vibration sensors and that IFM has one that connects via IOlink.
Thanks!
r/PLC • u/wigspltr16 • 1d ago
Had some weird Internet stuff happen and now i have entire rio rack faulted with error 16#0118 that wont clear. Tried older program and also changing module also tried disabling handshake and mismatch identity still wouldnt clear.
Last we have metler toledo scale heads (at least 6 of then faulting with error16#0204.
Any info i could learn id greatly appreciate.
r/PLC • u/LimboGuy69 • 1d ago
Hello, I am doing my first project ever using servo motors but i am using a Siemens s1200 and it seems that there isn’t any mc torquelimiting so I have to use a Siemens made block called TorqueFB_TEL750. But I can’t really grasp what every input does or output. There doesn’t even seem to be a mode option for fixed stop detection or torque mode. Is there anybody who knows anything about this? And please do explain as if I am really stupid, servos are very new to me
r/PLC • u/bitter-for-better • 1d ago
I am beginner in learning plc. I want to go really in depth in allen bradly studio5000 for the starter. I came accross this SolisPLC and want to know if it is worth it. though i do not have any subscription of Studio5000 but i do have the software that was made to work like it. plclogix5000 by Logic Design. right now i am very confused whether i should enroll in SolisPLC. My goal is to learn in depth studio5000 from beginning ?
r/PLC • u/EmergencyHat2354 • 1d ago
Hi everyone,
Is it possible to communicate over PPI using the Siemens PC Adapter USB A2 (6GK1571-0BA00-0AA0)?
If so, how do I configure it to communicate with an S7-200 PLC in STEP 7 Micro/WIN?
Thanks for your help!
r/PLC • u/Mission_Procedure_25 • 1d ago
Hi all
Im currently commissioning a site and need some help with the drives.
One specific panel is giving us an error where after a power dip ( its Africa, so its frequent) the drives shows 44 - Switching on Inhibited (missing safety signal) even though the setting for safety check is off
Now a reset doesn't clear the issue, but p972 reset clears it and then i can go.
But is there anyway to prevent this?
r/PLC • u/_Tigglebitties • 1d ago
got a job in a bind, need to send 4-20mA to a plc to read live tank levels. clean fuel, slow level changes from pump inlet / outlet (no foaming or churning) , no explosion proof req'mt, ambient pressure and room temp, nothing crazy.
the engineers and contractors, in all their glory, spec'd and approved a sensor that wont fit in the tank. the correct sensor intended on plan set is a magnetostrictive float on a rod, but is 8-12 weeks out. plc vendor says they dont care what instrumentation is used, long as it sends 4-20. I have a radar level sensor in stock , IFM LW2720 . fits the bill, cut sheet says it'll work.
question is, before I play the hero and swap in radar, anyone have a reason to caution doing this?
the measurement task is really simple, far as demands from instrumentation, but I havent used radar before.
i've found other issues with using ultrasonic transducers drifting, or being fiddly, i've had submerged pressure transducers drift over time. never had issues with magnetostrictive, other than having to be sure to order the exact size for the tank ( exactly the issue here).
so i got this radar sensor to play around with to see if we can stock these as standard cause they'll work on every size / shape tank we integrate with so we dont have to rely on garbage info from plans / others. i just havent had time to put it through paces to be confident i wont shoot myself in the foot.
r/PLC • u/Feisty_Balance3409 • 1d ago
We have a global manufacturing footprint and as such, use a global SI who is supported at each location by local SIs.
In any given month 5-10 different engineers can access a sites PLC to make project edits or improvements. We manage it well in terms of security and such but we’re completely loosing the change management. Sadly our change logs are excel sheets and there’s just too many to keep up with given the various sites. I’m seeing too many edits that are being made and not correctly recorded. If a change needs rolled back, we’re missing the detail as to why it was applied, potentially re introducing a bug that was fixed. It’s like managing children who don’t want to open an excel sheet!
We’re mainly Rockwell focused but some sites use Siemens. We have Rockwell asset center but it seems it’s fairly easy to bypass. We’ve explored Version dog, now Octoplant and there’s no way I’m getting that through the budget at £20K a site, even with bulk pricing it’s still a clean fortune.
Any other solutions you lot have come across in your fields? I need something that engineers can’t bypass but can still allow online edits and multiple users online at once. Any thoughts?
Thanks for reading. One frustrated maintenance director.
r/PLC • u/Effective_Permit2931 • 1d ago
I'm having trouble connecting a Delta DVP-14SS211T PLC to a Yaskawa SGD7S-120A servo drive.
I want to use the PLC to generate the control pulses for the servo motor. However, connecting it directly could burn out the servo drive's input, and I'll be using other PLC outputs to trigger relays. Is there any problem with connecting the 0V from the 24 VDC power supply to the 0V from the servo drive’s internal 12 VDC power supply at the common terminal of the PLC’s outputs?
r/PLC • u/MediumAlmondCap • 2d ago
Hi all, I'm looking for advice from anyone who has solved this cleanly in the Beckhoff ecosystem.
Context
Requirements
What we've looked at
Beckhoff support confirmed these three options. They didn't have anything more elegant.
What I'm used to
I come from a general software engineering background. There I'd expect a versioned, signed artifact (an installer, a package, a container image, anything similar) that moves tested code to production safely, can be checked, and can be rolled back. I'm surprised I can't find an equivalent here. This can't be an uncommon problem for Beckhoff OEMs.
Questions
Any war stories, or "don't do what we did" lessons are very welcome. Thanks!
r/PLC • u/Valuable-Heart-1007 • 2d ago
Hi everyone!
I work as a PLC programmer at GM, and my new role requires me to work with Siemens PLCs. My background is mainly with Rockwell Studio 5000, so I already have experience with PLC programming, troubleshooting, and industrial automation.
I need to learn Siemens STEP 7 as quickly as possible and become confident enough to work with it professionally.
I have access to STEP 7 Classic (SIMATIC Manager) and can dedicate about one hour per day to studying.
My main priorities are:
If you were in my position, what would you do to learn as quickly as possible?
Would you focus on official Siemens documentation, practical exercises, online courses, or studying real projects?
Are there any specific resources, exercises, or learning strategies you would recommend?
Since I already know Rockwell, I don't want to waste time learning basic PLC concepts I already understand. I want to focus on the Siemens-specific concepts and become productive as quickly as possible.
I'd really appreciate advice from people who have made the transition from Rockwell to Siemens!
Thanks!
r/PLC • u/TheCried • 2d ago
I'm curious if any of the more seasoned folks can shed some light on this design choice, or have a theory as to how this came to be.
I'm chasing a gremlin in a high volume low mix filler installed in the early 2000s. This machine has many instances where an output point will run to a relay contact or some switch, then back to an input point in the same rack. Then that input will be used in a permissive for a different output point, which will then run through some contacts to an input point. Currently I am 3 Output back to Inputs deep in my investigation. Why not just run 24V through the device to an input and write normal ladder?
1st Edit:
Processing img 3ldbrziwxpwh1...
2nd Edit: First PLC logic: Contains mostly run permissives that have to do with the machine main machine drive. Middle PLC logic: Has to do with the pump that the section of the machine needs to be able to function contains some run permissives. Last PLC Logic: Uses an MAOC (Rockwell Electronic Cam) for timing, this sets when to actuate the final solenoid.
Gremlin: Machine will randomly stop feeding for an amount of time - allegedly the exact same amount of time. The machine continues to cycle, just does not feed, so it's an interlock thing of some sort. These operators are legit and put a high speed camera on the machine so I do believe them.
This seemingly comes from a downstream machine, as the downstream machine does show a fault on their MES, but it doesn't actually catch a fault code.
This issue has been going on for a few years at this point from what I can gather.
r/PLC • u/CartographerBrave485 • 2d ago
Hi this might be a bit basic but i cant find any way to do this in Kinco Dtools 4.5. When the HMI restarts from power loss i want to be able to see data stored in USB1 in my graph, but all i get from googling it refers to the pro version, if there is a way to progam it from macros it would be fine to. Sorry if this is not the right sub for this question but its the closest active one i can find to it.
Edit: I did it using a "Data report curve"
r/PLC • u/Live-BBQ • 2d ago
we upgraded the software of one machine and i asked the programmer to give me the programme so i can read at home but it not opening in my pc , i have V19 and i think that programmer had V20 or V21. What can i do to get access the programme? Thanks